Pairing Devices
Pairing without A remote
Step 1: Press the test/silence button on one of the smoke alarms 4 times, the green LED will rapidly flash continuously, indicating it has entered the transmitting mode (valid time: 60 seconds) .
Step 2: Press the test/silence button on each of the other alarms twice, and the green LED will slowly flash continuously, indicating it has entered the receiving mode.
- If pairing is successful: The green LED of these alarms will stop flashing.
- If pairing has failed: The green LED will continue to flash for 60 seconds, then the red light will stay on for 2 seconds.
Pairing with A remote
Step 1: Press the test/silence button on all alarms twice, the green LED will slowly flash continuously, indicating it has entered the receiving mode.
Step 2: Press the Matching button ( )on the remote, and the red LED will light up, it has entered the transmitting mode. When the alarms have received the signal, the network will be paired.
- If pairing is successful: The green LED of these alarms will stop flashing.
- If pairing has failed: The green light will continue to flash for 60 seconds, and then the red light will stay on for 2 seconds.